Energy-efficient gas/fuel oil burner

Feature:

KIO burner is equipped with steel burner pipe for connection to burner block.

KIC is equipped with ceramic bushing, dispensing with burner block.

Jet velocity: low, medium, high, maximum 150m/s

Power: 1.5 - 2000KW

Modular design

High-speed pulsed burner, ignite and control directly

Extremely low level of pollutant emissions because of the best combustion

Meet all the heating requirements and adapt to all kinds of gases.

Installed on the top or side wall

Applications

1. Apply to various industrial stove and gas-fuel heater

Steel industry

Precious metals, nonferrous metals and light alloys industries

Minerals, rocks, etc.

Plastics, fiber materials, paper industries

For secondary combustion device

For drying apparatus and hot blast stove

For bell furnace, car bottom furnace, roller hearth furnace, step furnace , roaster and other heat treatment furnaces

2. Heating methods: directly or indirectly

3. Control mode: Intermittent: On/off, big/small fire (pulsed);Continuous: Constant excess air coefficient or air flow

4. Temperature of hot blast: 450℃

5. Flame profile: flat flame, short flame, long flame

Alphabetic flag

Flame profile

Flat flame

Short flame

Long flame

Adjustment range

Connections

Constant air flow

Big/small fire

Proportion of small fire

Furnace temperature

Temperature of combustion air

①Refers to the standard range

②The data refers to the approximation of the maximum load. Please refer to the specific performance curve for accurate figures. Ionization electrode current ≥5μA, the range of UV monitoring ionization current will be more wide.

③ Gas flow decreased with the rise of combustion air temperature, the power of burner reduction.

④ K burner becomes radiation heating flat flame burner if it's connected to burner block.

⑤ If R burner choose the continuously adjusting method, it can only co-use with burner brick, cannot use SiC ceramics combustion chamber.

⑥ If you need higher temperature please consaltation :Foshan DELK Energy Technique Co., Ltd.

LPG, natural gas, town gas, generator gas, fuel oil--installation data icon.

Model

Size

Maximum power

Note:combustion air normal temperature, Open combustion λ = 1.1

There will be about 10mm deviation, due to the existence of the weld.

The power of the producer gas burner is 90KW...etc.

Power and other data( fuel is natural gas)

Model

Ceramic bushing

Power

Burner

Length of flame

Gas pressure

Combustion air

Outlet velocity

Ignition current

Concerned with flame amplifier and ignition power.

①Natural gas L, cool air combustion, open combustion. Convert to standard power kw before gas flow calculation

②KIO 40 is a kind of ignition burner without adjustment.

③Flame temperature of K and R burner: 1600℃, H burner: 1500℃(in maximum power)

④The inner bore of burner brick (for KIO burners) tilts a angle of 6 degrees for R burner. For H burner, the inner bore of burner brick shapes cylindrical, measuring three times of inner diameter length (3XD).

⑤Dimension of KIO burner block may be calculated according to 4). For higher jet velocity, a smaller inner diameter may be chosen, close to the jet velocity of the KIC series burner.

⑥Diameter of flame is usually once to twice of burner brick outlet's.

⑦Reduced the power of burner will use different burner and ceramic flame pipe.

⑧If choose the burner R, a air volume regulating valve must be installed in the air pipe line.

Air preheating temperature and air pressure curve

Air preheating temperature

Air preheating temperature and gas pressure curve

Gas pressure

Power

Length of Burner pipe for KIO burner

According to the type of burner, the length of burner pipe is:

R, K burner L1=L2+15mm; H burner: L1=L2+65mm.

Length of Burner pipe for KIC burner

The depth of penetration is the sum of the length of steel burner pipe and ceramic bushing. Make sure the burner is in the furnace and the distance to the wall of furnace is less than 50mm.

KIO(A) burner is equipment with burner pipe

The length of burner L1 is the sum of the length of burner pipe and addutional burner pipe.

The position of the burner must be calculated by the fellowing formula(drawing 5): L2=W±50mm

Burner size

Recommended value

Length of additional tube

Burner H

Burner R

Other length can be customized

Application of KIO burner

Applicable field

Industrial furnace, open combustion

Radiant tube heating

Hot blast stove

drawing

Combustion chamber

taper, export open type

Cylindrical

Necking type

Flat flame burner brick

Additional flame pipe with secondary induced air aperture

Additional flame pipe with secondary induced air aperture Combustion chamber

Adjusting mode

Big/small fire Continuous

Big/small fire/off

Burner

Maximum power

about

Remarks

We recommended to use this installation when it's cold combustion, or the NOx in emission maybe too high.

Medium outlet velocity

Medium /Hign Jet velocity

  