The product model: FF, FM
Madas Gas Filter,filter, Industrial furnace with a filter.

Italy MADAS gas filter tests the pressure upstream through appropriate standard UNI-CIG. The precision fabrication of aluminum die-casting can ensure accuracy of the micro-filtration which is less than the requirement of UNI-CIG8042(50μm) in the flange and thread type of filter. The filter screen is made from washable composite. Regulation standard UNI-CIG8042 provides that an appropriate filter must be installed in front of the booster. Adapt to CNG, town gas,LPG and all kinds of corrosive gas and filtering.
Technical paratemers:

  1. Maximum operating pressure:2bar-6bar
  2. Applicable medium:CNG,town gas, LPG and all kinds of corrosive gas and filtering.
  3. Reaction temperature: -20℃—+70℃

4. Connection: Thread Interface (DN15-DN50) In line with EN10226 Standard,
Flange Interface (DN65-DN200) In line with ISO 7005 Standard;
5.NP: PN16F
Filter installation and maintenance:

  1. Filters usually should be installed before regulator, and must according to the specified in the direction of gas flow installation;
  2. Filter is made of synthetic materials , to facilitate the overall cleaning and maintenance, but move dismantle.
  3. Before the overhaul, please confirm that there are no gas in filter, pack off screen and using soap cleaning, then dry naturally, reinstall again.

Maintenance and matters needing attention:

  1. It must be installation by? professionals .
  2. After the completion of installation, must do leak test.
  3. , instantly gas shoulds not be too big when ventilation

Gas filter type:
FM 02 caliber:connection type:DN15 hickey nipple Max inlet pres.:2bar
FM 03 caliber:connection type:DN20 hickey nipple Max inlet pres.:2bar
FM 04 caliber:connection type:DN25 hickey nipple Max inlet pres.:2bar
FM 05 caliber:connection type:DN32 hickey nipple Max inlet pres.:2bar
FM 06 caliber:connection type:DN40 hickey nipple Max inlet pres.:2bar
FM 07 caliber:connection type:DN50 hickey nipple Max inlet pres.:2bar
FM 08 caliber:connection type:DN65 Flange interface Max inlet pres.:2bar
FM 09 caliber:connection type:DN80 Flange interface Max inlet pres.:2bar
FM 10 caliber:connection type:DN100 Flange interface Max inlet pres.:2bar
FM 11 caliber:connection type:DN125 Flange interface Max inlet pres.:2bar
FM 12 caliber:connection type:DN150 Flange interface Max inlet pres.:2bar

  