Natural gas solenoid valve,The EV/NC series gas safety solenoid valve
The product model: EVPF
Electromagnetic valve, electromagnetic valve gas, closed type electromagnetic valve, electromagnetic valve with kiln.
Gas safety electromagnetic valve is widely used for gas burner , atmospheric type gas burner, industrial furnace gas,incineration installation or other gas heating equipment control and adjustment. In strict accordance with the EN161 standards and CE testing rules production,accord with the European 90/396 / EEC, 94/9 / EC, 2004/108 / EC, 2006/95 / EC gas using standards.
Feature:
1,Electromagnetic valve has on both sides of the measure pressure (pressure relief) hole,diameter for 1/4 "
2, Adjust simple. Operation convenience etc.advantage.
3, Electromagnetic coils long time electricity, not burning, and ED output
4, Electromagnetic coils of insulation class for H (180℃).
5, Can maintain stability of power output and work with brand state the function of the output power decrease.
Technical parameters:
Connection mode:hickey nipple DN15~DN50
Accord EN10226 standard
Flange interface DN65~DN150
Accord ISO 7005 standard
Safety voltage: 24DC、24V/50HZ、100V/50HZ、230V/50-60HZ
Voltage tolerance: -15%—+10%
Working temperature:- 15℃—+60℃
MWP: 200mbar or 360mbar
Opening/closing time:<1second
Applicable medium: Natural gas, city gas, liquefied petroleum gas, air or no corrosive gas.
Valve material: Diecasting alloy aluminum
Valve installation instructions:
1, Before installation confirmed that the gas supply pressure shall not exceed the valve mark work pressure.
2, Before installation, the valve in the import and export of dustproof plastic cover from.
3 Confirmation airflow direction and the body in the direction of arrow mark is consistent.
4, with wall, ground have enough space (wait at least 30 cm) allowed free air circulation.
5, the valve can be along vertical direction + /-90 degrees installation; The direction of the coil for 360 degrees of any direction. 6, installation in from rain, the water splashed or the influence of water droplets place.
6. Installed in from rain, the water splashed or the influence of water droplets place.
Prouduct selection table:


Item

Connection caliber

MWP?? (mbar)

overall dimensions
A(wide)? mm

overall dimensions
B(high)? mm

Weight (Kg)

EVPF02

DN15

360

70

150

0.8

EVPF03

DN20

360

70

150

0.8

EVPF04

DN25

360

70

150

0.8

EVPF05

DN32

360

160

210

5.8

EVPF06

DN40

360

160

210

5.8

EVPF07

DN50

360

160

235

5.8

EVPF08

DN65

360

290

321

17

EVPF09

DN80

360

310

328

18

EVPF10

DN100

360

350

389

34.2

Italy elekrogas Quick opening and shut gas safety solenoid valves
Technial parameters:connection type:hickey nipple Rp3/8-1/2(yellow metal)hickey nipple Rp3/8-1/2-3/4-1-1 1/2-2 Flange interface DN65-DN80-DN100-DN125-DN150
Rated voltage: 230V AC 50/60Hz  、110V  AC  50/60Hz 、24V  AC/DC  、12V AC/DC
Voltage tolerance: 15%—+10%
Working temperature: -15℃—+60℃
MWP:max 200/360mbar
Opening/shut time:<1 second
Degree of protection: IP454
Cable: PG9
Sealing material:NBR rubber
Valve body material: Diecasting alloy aluminum
Applicable medium:Natural gas, city gas, liquefied petroleum gas, air or no corrosive gas.
Pressure inlet:Both sides G 1/4 (except brass series outside)
High pressure range: according from Rp 3/4 to DN150

  

About us | Product Manual | Contact us | User-centered

Copyright©2011 Foshan Delk Energy Technique Co., Ltd.   www.madas.com.cn   Retain all the power of interpretation ICP证编号:粤ICP备07005065号

If you want to solve the parameters and installation method of heat combustion system,such as proportional valve ,regulator valve, relief valve, Emergeny Cutoff Valves, Actuators + disc valves, Automatic ignition burner, pulse controller,UV probe.please browse our website!